Limitations: Floor decking, wall cladding, roof sheathing and interior finish material (such as gypsum wall board) need to be sized to span the added dimension without undesirable deflection. Since more insulation and less lumber is used, and since insulation has a higher R-value than lumber, increasing stud spacing increases the overall R-value of the wall system. Wider stud spacing contributes to energy efficiency by reducing the amount of lumber in a wall cavity. However, resource savings will occur regardless of economic savings. In general, simpler plans designed on a two-foot module are much more likely to result in savings with 24" on center framing than are complex plans with odd dimensions and many small offsets.
COLD FORMED STEEL FRAMING DETAILS HEADER TRIAL
A careful analysis or a trial prototype is needed to determine whether the wider spans make economic sense for a particular plan. The need for thicker deck sheathing will also offset a portion of the savings. Floor joists may need to be deeper for wider spans, but the reduction in lumber required for the building usually offsets the price increase from having larger floor joists. When first implementing advanced framing elements, crews are likely to be slowed down until they become more familiar with the method.īenefits/Costs: Approximately one-third of the lumber can be eliminated from the wall and floor framing of a value-engineered house, over walls and floors spaced 16 inches on center. Designs that are built repeatedly should include wall framing layout drawings to guide the framing crew.
![cold formed steel framing details header cold formed steel framing details header](https://www.realestateu.com/media/courses/uploads/2019/11/structural-systems4.jpg)
Bracing and fastening schedules and sheathing thickness requirements increase with framing spacing.Ĭareful spacing of window and door openings will maximize the economy of wider spacing.
COLD FORMED STEEL FRAMING DETAILS HEADER CODE
Installation: Installation should be in accordance with manufacturer’s specifications and model building code prescriptive methods. This strategy can be combined with modular layout and single top plate for added economy, but can also be used independently Roof framing that utilizes trusses is most frequently spaced at 24". The following list covers different principles that form an advanced framing system.ĭetails: Wall and floor framing spacing can often be engineered for 19.2" (1/5 of an 8-foot sheet) or 24" on center (1/4 of an 8-foot sheet).
COLD FORMED STEEL FRAMING DETAILS HEADER HOW TO
Accordingly, the user will note that some advanced framing techniques receive points for both Additional Information / How to Implement:Īdvanced framing elements can be applied independently, or adopted in the entirety, depending upon the specific requirement(s) of the project. An optimum value engineered assembly tends to use less energy for space conditioning because the omitted (and redundant) structural components can be displaced with insulation. Advanced Framing or Optimum Value Engineering refer to framing techniques that reduce the amount of materials used to build a home while maintaining the structural integrity of the home.